Terminals and Connectors: Torque, Contact Resistance and Thermal Cycling
Terminal blocks are the part of a driver that an installer touches, and they are also a common point of failure. The connection must carry the full output current for years, survive thermal cycling and resist corrosion, and it must do so with whatever wire and torque the installer actually applies. A terminal that is adequate on the bench can fail in a ceiling where the wire is strained and the screw was tightened by hand.
Screw clamps and push-in terminals behave differently. A screw clamp relies on the torque applied to compress the conductor, and the specified torque is part of the design: too little and the contact resistance rises, too much and the strands are damaged. A push-in terminal uses a spring to maintain force, which is more repeatable in the field but requires the correct wire size and, for stranded wire, a ferrule to keep the strands together.
Thermal cycling is the slow test. Current heats the terminal, the connection cools at night, and the cycle repeats. Materials expand at different rates, the screw can loosen, and the contact surface oxidizes. A joint that measured a few milliohms when new can drift upward over years, and the resulting heat accelerates the drift. This is why maintenance schedules include re-torquing terminals in high-current installations.
The current rating is not a single number. It depends on the wire gauge, the ambient temperature, the number of poles in the block and the way the block is mounted. A terminal rated for sixteen amperes at 20 degrees may be rated for less inside a sealed enclosure at 60 degrees, and the datasheet should be read with those conditions. Using the headline rating without the conditions is how terminals run hot.
Field practice is straightforward. Use the wire gauge the instructions specify, strip the correct length, use ferrules on stranded wire, and torque with a driver that has a setting rather than by feel. Keep the terminals clean and dry, and do not mix wire types in one clamp. After a year of operation, a thermal image of the terminal block shows hot spots that no multimeter reading would reveal.
For the PV100, the input and output terminals are rated for the currents the product delivers, and the installation instructions state the wire range and the torque. A project that runs the driver near its rated output should verify the terminal temperature after a few hours at full load, because the terminal is often the hottest accessible point. A warm terminal is not necessarily a fault, but one significantly hotter than its neighbours is worth investigating.
Contact resistance is the number that matters, not the clamping force alone. A clean copper-to-copper joint can sit at a fraction of a milliohm, while an oxidized or under-torqued joint can be ten times higher. At ten amperes the difference is a few watts of heat concentrated in a small volume, which is enough to discolour the plastic and soften the insulation over time. That heat is often the first sign a maintenance inspection finds, long before the connection fails outright.
The wire itself is part of the connection. Fine-stranded wire spreads better under a screw clamp than a few thick strands, and a ferrule makes the connection repeatable. Aluminium wire needs a terminal rated for it, because the oxide layer and the creep behaviour differ from copper, and mixing the two without a proper connector is a known source of failures.